Design Method of the Outlet Width of Centrifugal Pump When Handling Viscous Medium

陈晓玲,张武高,黄震
DOI: https://doi.org/10.3321/j.issn:1006-2467.2002.11.037
2002-01-01
Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University
Abstract:From the influence of viscosity of pumping medium on the boundary layer of centrifugal impeller, this paper presented the calculating methods of impeller boundary layer and outlet width. According to the calculation results, three different outlet impellers were designed for a certain range viscosity of pumping medium. The influence of outlet width of impeller on the performance of centrifugal pump was studied experimentally when handling different viscous fluids. The test results were also compared with that which is designed according to the method when handling water. At last, the design method of impeller outlet width were verified when pumping viscous medium.
What problem does this paper attempt to address?