Study on the Axial Velocity of Particles in a Liquid-Solid Circulating Fluidized Bed Using the Ultrasound-Doppler Technique

张欢,王铁峰,王金福,金涌
DOI: https://doi.org/10.3321/j.issn:1003-9015.2002.04.010
2002-01-01
Abstract:The ultrasound Doppler velocimetry (UDV) was used to investigate the transient axial velocity of particles and its time-averaged behaviors in a liquid-solid circulating fluidized bed. The standard deviation was used to scale the fluctuation of the transient axial velocities of particles. The experimental results showed that the radial profile of the mean axial velocity of particles under the circulating fluidization is considerably different from that without circulation. With the increase of superficial liquid velocity, the fluctuation of transient velocities decreases, and the mean axial velocity of particles increases approximately linearly in the core region and does not vary considerably in the wall region. With the increase of particle circulating rate, the fluctuation of transient velocities decreases first and then increases, and the mean axial particle velocity increases first and then reaches a saturation profile. The comparison of the probability distribution of the transient velocities and radial profile of the mean velocity with GSCFB confirmed that the particles are homogeneously dispersed in the liquid.
What problem does this paper attempt to address?