Deactivation Mechanism for COS Hydrolysis over TGH Catalyst - FT-IR Study of the Adsorption Behavior of COS, O2 and H2S

Meisheng Liang,Chunhu Li,HanXian Guo,Kechang Xie
2002-01-01
Journal of Natural Gas Chemistry
Abstract:The adsorption of COS, H2S, and O2 by FTIR at 50°-100°C was studied to find out deactivation mechanism for COS hydrolysis. The reaction temperature had a great influence on TGH catalyst deactivation. High reaction temperature could accelerate the poison of the TGH catalyst. When H2S and O2 existed hand-in-hand during COS hydrolysis process, the poisoning of TGH catalyst could happen. The deactivation mechanism was schematically depicted. The FTIR results of COS + H2S + O2 co-adsorption on the TGH catalyst showed that the main causes of catalyst deactivation was the formation of sulfur and trace sulfate.