3-D Positioning System Based on Linear CCD Camera

骆文博,王广志,丁海曙,秦志军,吴剑
DOI: https://doi.org/10.3321/j.issn:1000-0054.2002.09.002
2002-01-01
Abstract:A calibration method was presented for a three dimensional positioning system. Three high -resolution linear CCD (charge coupled device) cameras with wide -angle lens were used to provide a large field of view, but image errors due to large lens distortions occured as well. A modified camera model was used to correct the distortions. The proposed calibration procedure consists of two steps to correct the lens distortion and to avoid non -orthogonality problems arising in the ordinary direct linear translation (DLT) method. The performance of the calibration procedure was tested with real images, with a 1‰ accuracy achieved. The method can be extended to various photogrammetry applications.
What problem does this paper attempt to address?