Detector correction in large container inspection systems

Kang Kejun,Liu Yinbing,Chen Zhiqiang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2002.05.003
2002-01-01
Abstract:In large container inspection systems, the image is constructed by parallel scanning with a one-dimensional detector array with a linac used as the X-ray source. The linear nonuniformity and nonlinearity of multiple detectors and the nonuniform intensity distribution of the X-ray sector beam result in horizontal striations in the scan image. These factors greatly impair the image quality, so the image needs to be corrected. The correction parameters are determined experimentally by scaling the detector responses at multiple points with logarithm interpolation of the results. The horizontal striations are eliminated by modifying the original image data with the correction parameters. This method is proven to be effective and applicable in large container inspection systems.
What problem does this paper attempt to address?