Effect of Skin Movement on the Measurement Accuracy of Human Hand 3-D Motion

杨义勇,王人成,黄昌华,金德闻
DOI: https://doi.org/10.3321/j.issn:1000-0054.2002.08.019
2002-01-01
Abstract:The influence of skin movement on the accuracy of 3-D measurements was studied by experimentally analyzing pinching of the index finger and the thumb. The results were used to develop a 3-D hand motion analysis system. Tests show that, 1) the relative deformation of the area and length of surface markers on the finger is less than 5%, when the optimal marker configuration for each segment is used, so the effect of skin movement on the analysis of finger motion can be negligible. 2) The skin motion has different effect in the measurement accuracy for different joints. Relatively larges errors accuse with the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints, with small errors for the distal interphalangeal (DIP) joint. 3) The errors strongly correlate with the finger pinching motion, especially when the pinching cycle percentage reaches 60%.