Study of Continuous Countercurrent Extraction of Hydrocortisone with Centrifugal Extractor

于文东,段五华,张成群,周秀珠,李凤岐,周嘉贞
DOI: https://doi.org/10.3321/j.issn:1003-5214.2001.10.017
2001-01-01
Abstract:Extraction of hydrocortisone is studied with annular centrifugal extractor. When hydrocortisone is extracted from the zymotic fluid with butyl acetate, the mass transfer is controlled by diffusion rate only, and the distribution coefficient increases with the concentration of equilibrium aqueous phase. The technological process of continuous countercurrent extraction of hydrocortisone with annular centrifugal extractor is developed. When the rotor speed is 3400 - 3800 r/min, the total throughput is 40-75 mL/min, and V(O) is 0.35:1 - 0.42:1, the extraction efficiency of hydrocortisone is 91.08% - 93-16%. The extraction efficiency of the technological process used currently in plant is 90% when V(O) : V(A) is 0.7:1. So the new technological process increases the extraction efficiency of hydrocortisone and decreases the consumption of extractant.