The Attenuation of Gaseous Detonation Strength as a Result of the Bumper-Separator in Expanding Cavity of the Detonation Arrester

周凯元,李宗芬,周自金,王汉良,年伟民
DOI: https://doi.org/10.3321/j.issn:1001-1455.2001.03.004
2001-01-01
Abstract:Flame arresters and detonation arresters are used to prevent propagation of deflagration or detonation flame through flammable gases in industrial field. There are more difficulties in quenching detonation flame, especially over-driven detonation. For a detonation arrester whether or not the flame could be quenched successfully depends on not only construction but also element. A spherical bumper-separator was installed in the expanding cavity of the detonation arrester. When detonation wave arrives at the bumper it will be compelled to diffract, whereas a reflecting shock and a diverging shock will be produced at the front and back surface of the bumper-separator respectively. The paper first describes the experimental study on the attenuation of the shock of detonation as a result from the bumper, and gives out the experiment data of attenuated extent of shock pressure for different detonation velocity, then contrasts aforementioned data with those without bumpers. Meanwhile the advantageous influence of bumper separator on the flame quenching of detonation was related in this paper.
What problem does this paper attempt to address?