Abstract:A test system of fiber optic displacement sensor (FODS) was developed and applied to measure Ag clad multi-core Bi2Sr2Ca2Cu3Ox (Bi2223/Ag) superconductor tape at liquid nitrogen temperature (77K). A method of intensity compensation was used to eliminate the fluctuation in light source and fiber attenuation. The sensor's transmission characteristics and calibration function were obtained at 77K. The stress-strain curve of the multi-core Bi2223/Ag tape was presented, and its stress-J(c) (critical current density) relationship provided a useful reference to the application of the tape, The obtained results reveal that: (1) this sensor system can normally work at 77K; (2) its linear operating range is up to 1.6mm; (3) multi-core Bi2223/Ag tape's stress-stain relationship and stress-J(c) relationship can be measured real time; and (4) it overcomes the weaknesses that cryogenic strain gauges can only measure the surface deformation of these kinds of composite tapes.