Electrical Ignition Of Pulverized Coal

WenJiao Li,Junhu Zhou,X. Cao,Kefa Cen
2001-01-01
Abstract:No-oil ignition aid combustor for the pulverized coal fired boilers, which using the method of electromagnetic induction, is presented. The primary air is injected into the ignition chamber from the center of its entrance; between the outside of the primary air tube and the inner side of the ignition chamber, encircle wind is injected into the ignition chamber. The velocity of the primary air and encircle wind can be adjusted. The density of the pulverized coal in the primary air can be adjusted from 0.2 similar to1.2kg coal/kg air. The velocities filed of the ignition chamber in the cold position show its mechanism for encircle wind's performance in preventing of the clinkering in the inner side of the ignition chamber. The ignition process of the pulverized coal is researched. The distribution of the temperature in the axial direction in the center of the chamber is presented. The experimental results show that this combustor can ignite the primary air with the pulverized coal very quickly, and have a stable operation.
What problem does this paper attempt to address?