Abstract:On the basis of synthetically analyzing the characteristics of three kinds of Phase Difference Correcting Methods for calibration or discrete spectrum, simulation study indicates: when there is no noise or noise is small the precision of the first Phase Difference Correcting Method(performing FFT analysis on two original sequences continuously sampled) is higher than that of the second method (performing FFT analysis on the original sequence and the former N/2 point) and the third method (constructing a new sequence by shifting the former N/2 points of original time-domain sequence by N/4 points, setting both the former and latter N/4 points to zero and performing FFT analysis on the original sequence and new one, the spectrum can be corrected by taking advantage of the phase difference of two corresponding peak spectral lines). Under the condition of big noise, the precision of the third Phase Difference Correction is higher than others'. As to the signals which involves closely spaced frequency compone nts (not less than 4 resolutions), the precision of the first and third Phase Difference Correcting Methods is higher than that of the second. In engineering application, it is recommended to correct the spectrum containing small noise by the first Phase Difference Correcting Method with Hanning window. The errors of amplitude, frequency and phase are under 1%, 0.011 resolution and 5 degree respectively.