Effect of Internal Resistance of Reference Electrode System on Electrochemical Impedance Spectroscopy

MC Li,CL Zeng,HC Lin,CN Cao
2001-01-01
Abstract:Electrochemical impedance spectra of 316 stainless steel in NaCl solutions with different concentration, which were measured by using reference electrode systems with different internal resistance, were presented. The results showed that the large internal resistance of reference electrode system induced capacitive high frequency phase shifting impedance measurement. It was also found that high frequency phases shifts were reduced with the decrease of solution resistance and the internal resistance of reference electrode system.
What problem does this paper attempt to address?