The arrangement and simulation of laser tracking system for measuring coordinate with distance-measured-only

Zhao-hui HU,Jia WANG,Yong-dong LIU,Jin-wen LIANG
DOI: https://doi.org/10.3321/j.issn:1002-1582.2000.05.002
2000-01-01
Guangxue Jishu/Optical Technique
Abstract:In ordinary laser tracking and measuring system, the target coordinates are determined by measuring the variation of distance and the turning angle. In the laser tracking and measuring system with distance-measured-only, the coordinate measurement can be made only by measuring the distance and variation of distance without the need of measuring the turning angle, so its measurement precision is high. The geometric parameters of this system may self-calibrate without standard ruler, and the reference system for measuring virtual coordinate is set up. Therefore the arrangement of multi-station measuring system, the selection of measured points, the convergence and error of the computation, and so on, must be analyzed. A mathematical model of self calibration in laser tracking and measuring system is presented at first. Then the Jacobian matrix of the equations is analyzed. The restriction on the arrangement of stations and measured points in the measuring system by self-calibration is deduced. Finally the conclusion is validated by computer simulation.
What problem does this paper attempt to address?