Parameters control and optimization during forced cooling process after shutdown of steam turbine

YuYang Zhou,Hanping Chen,Jianhua Xin,Chun Ye
2000-01-01
Abstract:Forced cooling with hot air obliged passing through the steam path after shutdown has been widely adopted for the severe competition in the open market. For the sake of tiny convection coefficient compared with vapour, the security analyses have been neglected which leads the ambiguity of the potential advantages of forced cooling. Based on the three-dimensional axial-symmetrical thermal stress computation for the rotor of a 600 MW steam turbine produced by Shanghai Turbine Co, some problems such as modelling, initial conditions for calculation and optimal control of cooling process were discussed.