Study on combustion characteristics of rice husk-fired fluidized bed boiler

Guanyi Chen,Mengxiang Fang,Zhongyang Luo,Chunjiang Yu,Xuantian Li,Mingjiang Ni,Kefa Cen
1998-01-01
Abstract:The experimental results of ignition and burn out characteristics of rice husk in fluidized bed combustion test rig were reported and analyzed. Ignition experiment shows that rice husk can be ignited easily at the lowest temperature of 340 C. Rice husk may be ignited well when fed into fluidized bed at the bed temperature of 400 C, and its devolatilization is prompt, but burning out is difficult. Combustion test shows: the combustion intensity is concentrated in dilute phase zone, so the temperature here is higher than that in the density phase zone. In the experimental conditions, the combustion intensity in middle zone of the bed is strongest. Reasonable parameters are listed below: velocity 1 m/s -2 m/s, dimensions fluidization number 3-7 and air split 7:3. Although rice husk char burns out difficultly, the combustion efficiency is still 97% high. All these results are very useful to design and operate rice husk-fired fluidized bed boiler in engineering.