3-DIMENSIOANAL COMPUTERIZED RECONSTRUCTION OF MYOCARDIAL ISCHEMIA FROM ELECTRON BEAM CT

Zhijian Song,Minguang Zhang,Guoqiang Wu,Tianzhen Shen,Huanchen Zuo
DOI: https://doi.org/10.3969/j.issn.0258-8021.1998.02.006
1998-01-01
Abstract:We reconstructed a 3-dimensioanal image of heart and the area of myocardial ischemia from 2-dimensioanal tomogram of electron beam CT (EBCT). The left circumflex branch of coronary artery were occluded to form ischemia of left ventricular lateral wall in six dogs. A series of heart section were obtained by using the enhanced volume scanning of EBCT. The ischemic myocardium was recognized in program in terms of area expanding method. Surface reconstruction was applied to constitute 3-dimensioanal image of whole heart. Pathological section was stained with Nitro-BT. RESULTS: The reconstructed 3-dimensioanal image of heart was realistically displayed. The position and configuration of ischemic region was identified accurately and quantitatively. CONCLUSION: Position and volume of infarction can be diagnose by using EBCT. The 3-dimensioanal reconstruction of myocardial ischemia could help physician to diagnose the focus of myocardial infarction more precisely than 2-dimensioanal image of EBCT.
What problem does this paper attempt to address?