Abstract:The optic fiber sensors were embedded in several concrete structures (such as cylindrical member, girder member, etc.) in order to measure in-situ the change in their internal-stress state in a real-time way when the structures are suffered from compression or bending. The relationship among the fiber output, the way the fibers are embedded, and the internal state of the concrete structures was investigated. The experimental results sow that though its sensitivity in detecting the internal stress and cracks remains to be improved, its sensitivity in monitoring the damage of the structures can meet the engineering requirements.