Reconstruction of A Large Tracheal Defect Using Gore-Tex and External Wire Stent

Huiqing Lin,Jie Huang,Hao Hu,Qing Geng
DOI: https://doi.org/10.1097/sap.0b013e31821d073a
2013-01-01
Annals of Plastic Surgery
Abstract:Reconstruction of a tracheal defect remains to be one of the biggest challenges in thoracic surgery. We present a case in which we used Gore-Tex and an external wire stent to reconstruct 7 cm of the trachea and obtained satisfactory outcomes. Gore-Tex appears to be a biocompatible, stable, and reversible material that can be safely used to reconstruct tracheal defects.
What problem does this paper attempt to address?