Online Measurement of Water Concentration of Oil–water Mixtures in the Flow of Pipeline by Using Eddy Current Method

Zilian Qu,Qian Zhao,Yonggang Meng
DOI: https://doi.org/10.1088/0957-0233/24/12/125304
IF: 2.398
2013-01-01
Measurement Science and Technology
Abstract:Measurement of water concentration of oil-water mixtures in a pipeline is important in the oil industry. Capacitance, gamma-ray and ultrasonic techniques have been developed for the purpose of water-cut measurement for years. In this paper, we demonstrate a new non-contact method, which uses an eddy current sensor to monitor the flow in a pipeline based on the relationship between the water-cut of the flow and the inductance of the sensor. A simulation model and a simple experiment setup are presented. The experimental results have shown that the measurement error for water-cut over the range of 0-100% is less than 4.5%.
What problem does this paper attempt to address?