Abstract:To promote engineering application of municipal sludge pyrolysis technology, pilot-scale sludge pyrolysis device integrated systems were set up to study the effectiveness of sewage sludge pyrolysis. The experiment showed that the best final temperature was 450~500°C and residence time was 30~40 min. Under the conditions, 50% reduction rate of dried sludge and 17.1% yield of pyrolysis oil with 33.8MJ/kg of calorific value were obtained by optimization. Through energy balance analysis, energy produced from pyrolysis oil and gas together or just from sewage-char is almost sufficient to supply the energy required for sewage sludge pyrolysis, then this could accelerate the engineering application of sludge pyrolysis process.