Improvement on gas sample preparation of odor test and study on influencing factors

颜鲁春,刘杰民,冯振华,伊芹
2013-01-01
Abstract:Gas sample preparation is fundamentally important for odor tests and relative scientific research, and directly affects the precision of test results. The traditional way, triangle odor bag method, is to inject liquid standard reagents into a 3L odorless bag with micro-syringe. The fluctuation of sample volume can influence the precision and stability of sample preparation, which should be possibly reduced when preparing the odorants with low thresholds or samples at low concentration levels. In the present work, a two step preparation method was established by injecting standard reagents into a 100 mL glass syringe and then transferring part of the well volatilized and mixed gas into the odorless bag. The results showed no distinct difference of precisions between the two methods, but our two-step one showed better stability. At the same time, we found that ordinary odorants could completely volatilize and mix well within 3 min after being injected into odorless bags. The concentrations of odorants in the odorless bag kept constant in 20 min after preparation except for those with strong volatility and adsorptivity.