Abstract:Medical waste incineration is widely applied in China to reduce and treat the hazardous hospital waste in numerous cities. Due to the strong public opposition, it is necessary to more deeply clean the flue gas, to determine rapport proof and lenient way for green environment. Eleven soil samples were collected in the vicinity of a medical waste incinerator (MWI) and one fly ash sample (FA) of MWI in East China; moreover, open burning ash (OBA) was sampled in a nearby village. These samples were analyzed both for heavy metals and dioxins, or more precisely the seventeen 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), two major parameters of interest. Some heavy metals concentrations (As, Cd, Pb, Zn) in soil even exceeded from China Environmental Quality Soil Standard (level II and III). The potential reasons for these huge heavy metal values were examined. International Toxic Equivalent (I-TEQ) of PCDD/Fs in soil range from 1.33-10.4 pg/g, with an average value of 4.17 pg/g; these levels are comparable with those published elsewhere. Principal component analysis (PCA) was used to test the relationship between soil samples, OBA, and FA, and between heavy metals and dioxins. The results suggested that this particular MWI is not a strong source of deposition of heavy metals and PCDD/Fs in its surroundings, since these are unrelated.