Mechanical behavior tests of NiTi wires with different diameters for structural vibration control

Hui QIAN,Jing-bin LI,Hong-nan LI,Huai CHEN
DOI: https://doi.org/10.3969/j.issn.1000-3835.2013.24.016
2013-01-01
Abstract:Cyclic tensile tests of superelastic NiTi SMA wires with three diameters were conducted. The effects of different loading conditions including cyclic loading-unloading number, strain amplitude, loading frequency and ambient temperature on the mechanical behavior described with some fundamental quantities, such as, transformation stress, energy dissipation per cycle, secant stiffness, equivalent damping ratio and residual strain were examined. The temperature changes of SMA wires due to the latent heat under different loading conditions were analyzed. The results showed that with increase in the cyclical number, the martenside transformation start stresses of all the three specimens decrease, the energy dissipation per cycle and the secant stiffness gradually reduce, while the residual strains increase; however, all of them tend to be stable after 20 cycles; under the same conditions, damping and re-centering properties of φ 0.5 millimeter SMA are superior to the other two, but the mechanical behaviors of φ1.2 and φ2.0 millimeter SMAs are basically close to each other. The test results provided a basis for design of SMA dampers.
What problem does this paper attempt to address?