Numerical simulation of orifice plate reducing gas pulsation

Wenjie Bai,Yongquan Li,Xumeng Xie,Quan Duan
DOI: https://doi.org/10.11776/cjam.30.06.D058
2013-01-01
Abstract:It is difficult to determine whether using orifice alone can reduce the pulsation of hyper compressor pipeline or not. To solve this problem, firstly, the principle of reducing pulsation with orifice and buffer is enunciated. Then the hyper compressor outlet pipe for LDPE (Low-Density Polyethylene) plant is taken for an example. A two-dimensional non-steady flow model is established by using the numerical simulation software FLUENT. The pulsation conditions of pipeline with orifices of different aperture ratios are calculated and compared with the situations without orifices. According to the obtained numerical results, adding the orifice individually with appropriate size can reduce pulsation to some extent, and the smaller the aperture ratio is, the better result can be reached. The orifice of aperture ratio 0.4 can reduce pulsation by about 50% and the orifice of aperture ratio 0.3 can reduce pulsation to 38% of the original at the most. In addition, in order to achieve the best overall efficiency, the resistance of orifice and the follow-up process conditions should also be considered.
What problem does this paper attempt to address?