Rapid Start-Up of Biological Purifying Filter of Groundwater Containing High Concentration of Iron and Manganese Associated Ammonia Nitrogen

CHENG Qingfeng,LI Dong,LI Xiangkun,ZHANG Xiaojing,ZHANG Jie
DOI: https://doi.org/10.3969/j.issn.1000-4602.2013.07.010
2013-01-01
Abstract:Biofilter has a problem of long start-up period when it is adopted to purify groundwater containing high concentrations of iron,manganese and ammonia nitrogen.In order to investigate the effect of double-filtering media and circulation reflux on start-up,three starting modes were adopted in three same filters with double-filtering media,circulation reflux of single-filtering media and no circulation reflux of single-filtering media,respectively.The results showed that double-filtering media or circulation reflux was an effective way to shorten the start-up period.The total iron,manganese and ammonia nitrogen in the effluent of the three filters were below 0.3 mg/L,0.05 mg/L and 0.2 mg/L on the 82nd,81st and 103rd day,respectively.Iron was removed mainly in the depth of 0 to 0.4 m.Manganese was adsorbed by manganese sand at the beginning,and biological manganese removal was improved gradually after ammonia nitrogen was reduced to a certain extent.Manganese and iron were removed mainly in the depth of 0 to 0.4 m.
What problem does this paper attempt to address?