The Design of A Membrane Biosensor

Shengbo Sang,Wendong Zhang,Hui Feng,Pengwei Li,Jie Hu,Gang Li
DOI: https://doi.org/10.4028/www.scientific.net/kem.562-565.237
2013-01-01
Abstract:The need for high throughput label-free multiplexed sensors for biological sensing has increased in the last decade. In this paper, a new surface stress-based polydimethylsiloxane (PDMS) membrane biosensor for cellular detection is designed and fabricated. The geometric parameters of the PDMS membrane are optimized through the finite element (FE) analysis. One fiber optic interferometer biosensor test system is built to test the characteristics of the biosensor. The biosensor is further functionalized using 11 Mercapto 1 undecanoicacid (MUA: SH-(CH2)10-COOH) and tested in contact with cells - Escherichia coli (E. coli). The results of our experiments showed that cells can be detected based on the surface stress-based PDMS membrane biosensor. The new approach for cellular detection has good sensitivity and biocompatibility.
What problem does this paper attempt to address?