Simultaneous Measurement of Temperature and Refractive Index Using an Exposed Core Microstructured Optical Fiber
Xuegang Li,Linh V. Nguyen,Martin Becker,Heike Ebendorff-Heidepriem,Dinh Pham,Stephen C. Warren-Smith
DOI: https://doi.org/10.1109/jstqe.2019.2908557
IF: 4.9
2020-07-01
IEEE Journal of Selected Topics in Quantum Electronics
Abstract:We have demonstrated a novel scheme for simultaneous measurement of temperature and refractive index by using an exposed core microstructured optical fiber (ECF). The ECF allows for high sensitivity to refractive index due to the small exposed-core, while being supported by a standard fiber diameter cladding making it robust compared to optical microfibers. The sensor combines a fiber Bragg grating (FBG) inscribed into the core of the ECF and a multimode MachZehnder interferometer (MZI). Both the FBG and MZI are sensitive to refractive index (RI) and temperature through a combination of direct access to the evanescent field via the exposed-core, the thermo-optic effect, and thermal expansion. The FBG and MZI respond differently to changes in temperature and RI, thus allowing for the simultaneous measurement of these parameters. In our experiment, RI sensitivities of 5.85 nmRIU and 794 nmRIU, and temperature sensitivities of 8.72 pmC and 57.9 pmC, were obtained for the FBG and MZI respectively. We demonstrate that a transfer matrix approach can be used to simultaneously measure both parameters, solving the problem of temperature sensitivity of RI sensors due to the high thermo-optic coefficient of aqueous samples.
engineering, electrical & electronic,optics,physics, applied,quantum science & technology