Reliability Evaluation for Iced Tower Based on Ultimate Bearing Capacity Analysis

Chenguo YAO,Yu LI,Zehong ZHOU,Chengxiang LI,Lei ZHANG,Zhou ZUO
DOI: https://doi.org/10.3969/j.issn.1003-6520.2013.11.006
2013-01-01
Abstract:For solving the difficulties in reliability analysis of transmission towers, through combining the ultimate bearing capacity obtained from non-linear buckling analysis with the reliability analysis of tower, we evaluated the safety of iced towers from the perspective of integral structural response. Choosing a certain part of the transmission lines in north China as the example, we established a tower-line finite element model of the line, and obtained the weakest tower of the line through calculations using the model. Then, using the elastic modulus and strength of the tower material, we calculated a sample of the ultimate bearing capacity of the weakest tower. Based on the sample, the type of distribution and the parameters of the ultimate bearing capacity were acquired. Finally, using the first-order second-moment method, the reliability of the weakest tower under different work conditions was calculated. An instance analysis proves that using the proposed method can effectively avoid difficulties existed in the failure-mode-based methods.
What problem does this paper attempt to address?