Calculation of Transient Leakage Current and Potential Distribution in Soil Around Railway Connecting Ground Wire under Lightning

WU Guangning,LI Tianzhi,CAO Xiaobin,ZHOU Lijun,WEI Minmin,DUAN Xudong
DOI: https://doi.org/10.3969/j.issn.1003-6520.2013.04.027
2013-01-01
Abstract:In order to research the transient potential distribution and leakage current flow regularity in soil of connecting ground wire,we used an infinite horizontal grounding body model instead of connecting ground wire to calculate the effective length under impulse current.Then,we obtained the segment current and leakage current by an improved circuit model,and proposed a solution of specified potential by the electric axis method combined with the spark discharge effect.The results show that,about 99% of the injected current leaks while the current spreads 60 m along earth electrodes under given conditions;the highest potential on the connecting ground wire at the current injection point is 58.68 kV and the largest radius of spark discharge is 14 cm.Compared with traditional methods,the proposed method takes the attenuation of current and the increase of equivalent conductor radius caused by spark discharge into consideration in earth calculation,so the results are closer to actual values.By taking the spark discharge's effect into consideration,the potential distribution obtained from electric axis method has no change in pattern,but its amplitude decreases by about 10%.
What problem does this paper attempt to address?