Abstract:An automatic four spectral bands infrared radiometer system was designed for measuring the sea surface temperature. The principle of temperature measurement was given and the optical system was designed, which was divided into long-wave and medium-wave infrared optical system by using a spectroscope. Three long-wave infrared spectral bands were obtained through three long-wave infrared filters in the long-wave infrared optical system, respectively, which were 8- 13μm, 10.3- 11.3μm and 11.5- 12.5 μm. Similarly, a medium-wave infrared spectral band (3.5- 4.0 μm) was acquired by a medium-wave infrared filter in the medium-wave infrared optical system. The film system transmittance curves of the four infrared spectral bands were given, showing that the desired effect about narrow-band light pass was achieved. Furthermore, the modulation reticles in the long-wave and medium-wave infrared optical system were designed to modulate the object infrared radiation. The accuracy of the system was better than 0.5 K.