Distribution Profile, Health Risk and Elimination of Model Atmospheric Svocs Associated with A Typical Municipal Garbage Compressing Station in Guangzhou, South China

Guiying Li,Hongwei Sun,Zhengyong Zhang,Taicheng An,Jianfang Hu
DOI: https://doi.org/10.1016/j.atmosenv.2012.06.027
IF: 5
2013-01-01
Atmospheric Environment
Abstract:Semi-volatile organic compounds (SVOCs) air pollution caused by municipal garbage compressing process was investigated at a garbage compressing station (GCS). The most abundant contaminants were phthalate esters (PAEs), followed by polycyclic aromatic hydrocarbons (PAHs) and organic chlorinated pesticides (OCPs). Sigma(16)PAHs concentrations ranged from 58.773 to 68.840 ng m(-3) in gas and from 6.489 to 17.291 ng m(-3) in particulate phase; Sigma(20)OCPs ranged from 4.181 to 5.550 ng m(-3) and from 0.823 to 2.443 ng m(-3) in gas and particulate phase, respectively; Sigma(15)PAEs ranged from 46.498 to 87.928 ng m(-3) and from 414.765 to 763.009 ng m(-3) in gas and particulate phase. Lung-cancer risk due to PAHs exposure was 1.13 x 10(-4). Both non-cancer and cancer risk levels due to OCPs exposure were acceptable. Non-cancer hazard index of PAEs was 4.57 x 10(-3), suggesting safety of workers as only exposure to PAEs at GCS. At pilot scale, 60.18% of PAHs, 70.89% of OCPs and 63.2% of PAEs were removed by an integrated biotrickling filter-photocatalytic reactor at their stable state, and health risk levels were reduced about 50%, demonstrating high removal capacity of integrated reactor. (C) 2012 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?