Experimental study on features of galloping response of tower-line system for transmission

杨伦,楼文娟,陈勇,阎东
DOI: https://doi.org/10.13245/j.hust.2013.11.026
2013-01-01
Abstract:To investigate the dynamic responses of transmission tower-line systems caused by conductor galloping, taking a strain resistant corner tower as a prototype with cross arm seriously damaged under iced conductor galloping disaster, a tower segmental model with elastic boundary condition and conductor model of different ice thickness were founded by the similarity theory of dynamic model, and the vibration experimental equipment used to simulate galloping responses of iced-conductor was developed at the first time. On this basis, the dynamic tension and vibration features of galloping conductor were reconstructed under the laboratorial conditions. Then the galloping experiment of transmission tower line was carried out, and the effects of ice thickness, galloping amplitude and frequency on dynamic response of transmission tower-line system were discussed. The results shows that the galloping of iced-conductor cannot result in the resonance of transmission tower, and the galloping response of the tower-line coupling system increases with the raise of ice thickness, the galloping amplitude and frequency. Furthermore, compared with dynamic tension and strain of members, the dynamic response of transmission tower is more sensitive to the vibration of the galloping amplitude and frequency.
What problem does this paper attempt to address?