Simulation accuracy using CFD investigations of flowrate measurement

赵会超,彭黎辉
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2013.07.021
2013-01-01
Abstract:Computational fluid dynamics (CFD) analyses have been widely used to investigate fully developed turbulent flows in cylindrical smooth pipes. This paper takes into account various aspects of turbulent flow analyses including meshing, turbulence model selection, and wall treatment functions in CFD investigations of accurate flowrate measurements. The friction coefficient, the turbulent entrance length and the semi-empirical equation model of the velocity distributions are used as the evaluation criteria. The appropriate meshing strategy, the selection of the RNG k-ε turbulence model and the enhanced wall treatment (EWT), and the use of a long entrance length give satisfactory simulation results for CFD aided investigations of flowrate measurement techniques. A case study of a multi-path ultrasonic flowmeter shows that that the error between the experimental data and CFD simulation is within 0.3%.
What problem does this paper attempt to address?