Abstract:It has been found that the measured exit temperature distribution of the DLN combustor of R0110 heavyduty gas turbine deviates from design expectation. In order to reveal the reason, the dilution zone as geometrical model is investigated numerically. Several influence factors, such as temperature and velocity profiles of upstream hot gas and dilution characteristics, are studied. The results show that the reverse-flow structure of annulus generates an irregular flow field and results in much higher mass flow rate through lower dilution holes than through upper ones, which pushes up the radial position of the hot zone. Jet angles have great effects on temperature distribution. The sharp temperature drop both at blade tip and root is caused by air leak near the exit section.