The Echelle Grating Monochromator's Design of Pure Rotational Raman Lidar

Ge Xian-ying,Chen He,Zhang Yin-chao,Chen Si-ying,Guo Pan,Mu Tao-tao,Bu Zhi-chao,Yang Jian
DOI: https://doi.org/10.1117/12.2034950
2013-01-01
Abstract:The pure rotational Raman lidar temperature measurement system is usually used for retrieval of atmospheric temperature according to the echo signal ratio of high and low-level quantum numbers of N-2 molecules which are consistent with the exponential relationship. An effective method to detect the rotational Raman spectrum is taking a double grating monochromator. In this paper the detection principle and the structure of the dual-grating monochromator are described, with analysis of rotational Raman's Stokes and anti-Stokes spectrums of N-2 molecule, the high order and lower order quantum number of the probe spectrum are resolved, then the specific design parameters are presented. Subsequently spectral effect is simulated with Zemax software. The simulation result indicates that under the condition of the probe laser wavelength of 532nm and using double-grating spectrometer which is comprised by two blazed gratings, Raman spectrums of 529.05nm, 530.40nm, 533.77nm, 535.13nm can be separated well, and double-grating monochromator has high diffraction efficiency.
What problem does this paper attempt to address?