Abstract:The mixing of liquid addition in a stirred tank installed with a helical ribbon impeller under laminar flow regimes during inoculation in the simultaneous saccharification and fermentation of lignocellulosic biomass at high solids loading was studied. The effects of impeller rotational speed, volume ratio of added liquid a to bulk liquid b, Va/Vb, and their viscosity and density on mixing time, tm, were examined. The results show that it takes longer time for the liquids with different viscosities and densities to get homogenization than that of similar property liquids when Va/Vb is above 1%. tm of the liquids with different properties is 2~5 times longer than that of similar property liquids at identical conditions. Va/Vb is the most important operating parameter, dimensionless mixing time, Ntm, first decreases and then increases with Va/Vb, there is a minimum value. When Va/Vb ≥ 2% and Δ/ρb > 0.2, Ntm increases linearly with them. Liquid addition in the bulk has shorter mixing time than that of addition on the surface. The mixing regime in the tank can be classified into Re controlled (stirrer controlled) regime and Ri controlled (gravity controlled) regime at high Va/Vb (2%).