Experimental study of the mechanism governing the HAT (humid air turbine) cycle performance of a split-shaft micro gas turbine

Qiang Pu,WEI Chen-yu,Bin Ge,ZANG Shu-sheng
2012-01-01
Abstract:Based on a split shaft micro gas turbine and through a saturator additionally installed, constituted was the HAT cycle performance test rig of the turbine. On this basis, tests of the mechanism governing the HAT cycle performance were carried out. The test results show that after the air is humidified, it has a conspicuous influence on the cycle performance and both specific power and efficiency of the cycle have a very big enhancement when compared with that of the simple cycle. When the humidification quantity reaches its maximum of 4.2%, the output power of the cycle will increase by 16%. The simulation results under the test conditions are in very good agreement with the test ones. On this basis, a simulation calculation was performed of the test system with a recuperator. The calculation results show that under the condition that the initial gas temperature is kept unchanged, the incorporation of the recuperator will result in an increase of the pressure loss of the system and the specific power of the device will decrease by about 3%-10%, however, in the meantime, the oil consumption rate will lower by 20%-45% and the efficiency will go up by 30%-80%. In such a case, the performance of the system is markedly enhanced.