A Comparison of the HAT (Humid Air Turbine) Cycle Performance of a Micro Gas Turbine With and Without an Aftercooler

WANG Bo,ZHANG Shi-jie,XIAO Yun-han,Zhen Xu
2010-01-01
Abstract:Compared was the performance of a 80 kW micro gas turbine recuperative cycle after its conversion to a HAT (humid air turbine) cycle with and without an aftercooler. The needed increase in the heat exchanger area is given. The research results show that for the gas turbine under investigation,both the conversion efficiencies and power outputs of the HAT cycle system with and without an aftercooler are nearly the same. Compared with the HAT cycle having an aftercooler,the cycle without an aftercooler is equipped with a humidifier of a greater height and volume. The total heat exchange area (sum of the heat exchange areas of the aftercooler,humidifier and economizer),however,becomes smaller in the absence of the aftercooler. This means that the total investment will be lower,and the configuration of the HAT cycle system,more simple,thus making the system more compact and its control easier.
What problem does this paper attempt to address?