The Application of Phase Contrast Imaging to Implosion Capsule Diagnose in High Energy Density Physics Environment

Yan Ji,Zheng Jian-Hua,Chen Li,Lin Zhi-Wei,Jiang Shao-En
DOI: https://doi.org/10.7498/aps.61.148701
IF: 0.906
2012-01-01
Acta Physica Sinica
Abstract:The variation of multi-layer shell capsule in implosion process is the most important part of inertial confinement fusion.Phase contrast imaging which relies on gradients of the refractive index and wave interference is proposed to characterize the typical implosion capsule.The experiments are performed on the ShenguangⅡlaser facility.The point-like X-ray source at 4.75 keV can be efficiently produced from laser interactions with Ti target and observed by pinhole-point backlight technique.The phase contrast images obtained with point-like X-ray source provide complementary information about the multi-layer shell capsule,and the spatial resolution is better than 10μm.The X-ray phase contrast imaging shows more detailed features than absorb imaging,and good agreement with one-dimensional numerical simulations.
What problem does this paper attempt to address?