Diagnostic value of transrectal ultrasound-guided saturation prostate biopsy after initial negative result

Ning XU,Xue-yi XUE,Xiao-dong LI,Yong WEI,Tao JIANG,Rui GAO,Hui-liang ZHOU,Qing-shui ZHENG,Jin-bei HUANG,Hou-ping MAO
DOI: https://doi.org/10.13929/j.1672-8475.2012.09.010
2012-01-01
Abstract:Objective: To investigate diagnostic value of transrectal ultrasound-guided saturation prostate biopsy protocols after initial negative biopsy result and to assess the efficacy and safety. Methods: A total of 120 patients with elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination after initial negative biopsy enrolled in this study and were randomly divided into extended biopsy group and saturation biopsy group, each group had 60 patients with repeat biopsy. The extended biopsy group used 12-core repeat biopsy and the saturation biopsy group used 24-core repeat biopsy. Periprostatic nerve block was performed in the two groups. The pain and discomfort were estimated based on visual analog scale (VAS). Results: There was no significantly different in age, serum total PSA, PSA density, prostate volume, transition zone volume, previous pathology, digital rectal examination VAS and postoperative complications between the two groups (all P>0.05). The total cancer detection rate of saturation biopsy group was higher than that of extended biopsy group (31.67% vs 15.00%, P=0.031), the improvement of cancer detection rate was higher only when the prostate volume was greater than 60 ml (P=0.033). Conclusion: The transrectal ultrasound-guided saturation prostate biopsy can improve the detection rate of prostate cancer after initial negative result, and does not increase complications.
What problem does this paper attempt to address?