Experimental study of inspection on a metal plate with defect using ultrasound lock-in thermographic technique

Jun Liu,Lei Qin,Qingju Tang,Yang Wang
DOI: https://doi.org/10.1016/j.infrared.2012.03.009
IF: 2.997
2012-01-01
Infrared Physics & Technology
Abstract:The ultrasound lock-in thermographic technique was developed to detect interfacial defects and cracks in a metal plate. Discrete correlation method (DCM), Fourier transformation method (FTM), Short Time Fourier transformation (STF) and Discrete Wavelet Transformation (DWT) algorithms were used to extract the characteristic information of the thermal wave signal generated by ultrasonic wave modulated. It is found that STF and DWT algorithms are available for analyzing the thermal wave signal generated by ultrasonic wave modulated due to higher signal-noise ratio. Experiments were performed to investigate the effect on the amplitude contrast and phase angle contrast by the ultrasound transducer position, initial sonotrode action force and modulation frequency, respectively. Experimental results show that transducer position closed to the defect, higher initial sonotrode action force loaded and optimal modulation frequency selected are help to detect the defects of metal plate using ultrasound lock-in thermographic technique. © 2012 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?