Liquid–liquid Microflows in Micro-Sieve Dispersion Devices with Dual Pore Size

H. W. Shao,Y. C. Lu,K. Wang,G. S. Luo
DOI: https://doi.org/10.1007/s10404-011-0914-2
2011-01-01
Microfluidics and Nanofluidics
Abstract:Here we present the liquid–liquid microflows and dispersion rules in micro-sieve devices with two different sized pores. The flow pattern, flux distribution and droplet size were investigated to discuss the effect of pore size deviation. Three flow patterns including dripping flow from a single active pore, dripping–dripping flow and dripping–jetting flow from two active pores were identified. A modified active pore model based on a pressure drop balance has been established. The model can predict the transition from a single active pore flow regime to a two active pore flow regime very well. In the latter regime, interactions between the small and large pores can result in dripping–dripping flow at low trans-pore flux and dripping–jetting flow at high trans-pore flux. Controlling the flow pattern in dripping–dripping flow is favorable to decreasing droplet polydispersity.