On-Line Auto Monitoring of Hcl Emission in Cold Rolling Acid Regeneration Unit

Xu Kai,Pan Yuqi,Wang Jinyou,Chen Xiong
DOI: https://doi.org/10.1166/sl.2012.2636
2012-01-01
Sensor Letters
Abstract:According to the characteristics of the emissions of the acid regeneration units of cold rolling factories, this paper proposes an on-line HCL monitoring system, which can be used to monitoring the percentage of HCL in the emission of the acid regeneration units. This system consists of the HCL wet sampling module and top monitoring data processing module. The sampling module integrates the wind speed and direction sensor, CL-analyzer, wet sampling equipment, precise liquid level detect and control equipment and PLC. The top data module adopts an industrial computer as the core. This system overcome the disturbance of high temperature, high humidity and mass powder of the emission gas and accomplishes the goal of on-line auto measuring, monitoring, storing, transferring and alarming of the HCL emission in cold rolling acid regeneration unit. This monitoring system has been proved to be effective and scientific in spot running.
What problem does this paper attempt to address?