2012-01-01
Abstract:Imaging and inspection of ultrasonic guided waves for an arc array have higher transverse resolution than for a line array for locating defects centered around the natural focus of the arc array. An imaging and inspection system is developed using ultrasonic guided waves of an arc array using multichannel array signals. The characteristics of elliptical cluster tracks (CECT) of an arc array with "single transmitter and multi receivers" are used by synthetic aperture focusing. The CECT image can be used for analyzing, explaining and improving the transverse resolution. Imaging experiments show that synthesis aperture focusing with CECT can be used for imaging and inspection of ultrasonic guided waves for an arc array with smaller imaging-sampling step distances (ISSD) to make the image smoother. The image is the smoothest when ISSD is about 1/3 of the wave length. Larger distances between the two array elements and larger central angles of the arc array may significantly increase the transverse inspection resolution. This method provides imaging and inspection of ultrasonic guided waves in larger plate-like structures.