Experimental study on seismic performance of Post-Tensioned Prestressed Precast Concrete beam-column assemblages

Xun Chong,Shaoping Meng,Qijian Pan
2012-01-01
Abstract:The construction that connects the beams and columns by post-tensioning tendons provides ductile connections. When subjected to seismic loading, nonlinear behavior occurs in the connections, while the beams and columns remain elastic. The precast reinforced concrete frame adopting this type of construction has the advantages of favorable self-centering capacity and high grades of durability, and furthermore, it makes the "beam-hinge" energy dissipation mechanism possible for large-span prestressed reinforced concrete frames. To study its seismic performance, four beam-to-column assemblages were tested under cyclic reversal loads. For two test specimens, the post-tensioned strands are bonded all through the beams, while for the others the strands are designed to be unbonded near the beam end. The test results indicate that inelastic deformation concentrates near the beam-column connections, while damage of the beam, column and joint is relative minor. Comparing with the common concrete structure, the test specimens show less loop area and poor energy dissipation capability, while the self-centering ability is preferable since the residual drift is quite small. For the specimens with partially unbounded strands, the energy dissipation capability is even smaller and the self-centering ability is more remarkable. The ultimate drifts of the four specimens are between 0.359~0.439, which are bigger than the required values of Chinese seismic design code, so the deformation ability of these beam-column assemblages is enough.