Study of fire resistance of high strength Q460 steel columns

Bing Liu,Weiyong Wang,Guoqiang Li,Guoxin Dai
2012-01-01
Abstract:The strength and elastic modulus of Q460 steel at elevated temperatures were experimentally studied by steady-state test and dynamic method. With consideration of the mechanical properties of Q460 steel at elevated temperatures and initial imperfections, the three methods, namely critical stress method, inverse calculation segment length method (ICSL) and CDC method, to calculate the load bearing capacity of steel columns were extended to obtain the load bearing capacity of Q460 steel columns at elevated temperatures. The results of the three methods were compared and validated by finite element analysis through an example. The critical temperatures of Q460 steel columns at certain load ratio were computed and compared with the results given in the code for fire safety of structures in buildings-CECS200: 2006. The study shows that the mechanical properties of Q460 steel are quite different from those of conventional steel, and the strength and elastic modulus decrease slowly with the increase of temperatures. The results from the three methods of calculating the load bearing capacity of Q460 steel columns are similar and agree well with the finite element method, and there is significant difference of critical temperature between Q460 steel and conventional steel columns, and the fire resistance design results given in the code for fire safety of structures in buildings-CECS200: 2006 are not applicable to Q460 steel columns.
What problem does this paper attempt to address?