Modeling, simulation and experimental research on pressure tracking valve

杜恒,魏建华,冯瑞琳
DOI: https://doi.org/10.3785/j.issn.1008-973X.2012.06.012
2012-01-01
Abstract:Large engineering equipment with damping system often needs to achieve that the pressure in the elastic element tracks the pressure in the actuator, which can make the system switch smoothly when the elastic element and the actuator are connected. In order to achieve this goal easily, safely and reliably, a pressure tacking valve was designed, and the corresponding mathematical model and the simulation model based on AMESim were established. The feedback link on the valve was analyzed, and the dynamic and static characteristics of the valve under the influences of the spool area, valve opening and damper damping were studied. When the spool diameter is 16 mm, the orifice diameter is 1 mm and the valve opening is zero, the pressure tracking valve has good static and dynamic characteristics of pressure tracking. The test bench was set up and the experimental research was performed. The results show that the pressure tracking error can be controlled in about 0.1 MPa and the stability of the valve is good. The elastic element and the actuator can switch smoothly in the system with the application of the pressure tracking valve.
What problem does this paper attempt to address?