Experimental studies to heat transfer characteristics of separated heat pipes

TANG Zhi-Wei,SHI Ming-Xing,HAN Ya-Fang,WANG Bai-Lin
2012-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:Some experimental studies were carried out to heat transfer characteristics of separated heat pipes, which based on the experiment device of separated heat pipes designed by ourselves. The studies were taken under the following conditions: the temperature was between 170°C and 250°C and the heat current was between 25 kW/m 2 and 50 kW/m 2. The evaporation and condensation were composed of seven 30 mm seamless steel pipe with a steel silk annular fins, the length of the pipes were 160 mm. The dimensions of silk annular fins were outside diameter 45 mm, thick film 1 mm, 4 mm pitch. The experimental results showed that the most optimum filling liquid ratio of separated heat pipes was between 18% and 38% by all capacity of pipes. According to the results of the experiments, the synthetical equation of the average coefficient of boiling heat exchanging in evaporator and of coefficient of heat exchanging Nusselt in condenser was fitted under the most optimum filling liquid ratio (24%).
What problem does this paper attempt to address?