Structure Analysis for Tunnel Longitudinal Deformation Based on Segment Dislocation Mode

Zhiliang Wang,Linfang Shen,Jianbin Xie,Ji Yao
DOI: https://doi.org/10.1016/j.proeng.2012.01.1056
2012-01-01
Procedia Engineering
Abstract:According to tunnel structure around joints, tunnel longitudinal deformation is analyzed and a three-dimensional finite element model is built based on segment dislocation mode. Tunnel structure stress analysis is conducted from two aspects of segment in the shear and bolt in the tension. The analysis results show: (1) Segment shear model. When segment dislocation reaches 0.03mm, the principal stressσ1 exceeds 3.0Mpa which is over concrete's tensile strength. Therefore, when convex tenon and concave tenon generate shear, there must be horizontal slipping and bolt is tensioned. (2) Bolt tension model. When joint opening value reaches 2mm, bolt stress exceeds 640Mpa, which is bolt's yield strength. When joint opening value reaches 6mm, which is the waterproof control standard for tunnel, bolt stress reaches 688.7Mpa, which is less than bolt's failure strength. The subway tunnel's structure safety should be controlled from the perspective of waterproof.
What problem does this paper attempt to address?