Abstract:The linear frequency modulation (LFM, also called chirp) coded pulse compression technique has been applied to ultrasonic time-of-flight diffraction (TOFD) testing. After simulations were carried out for analysing the effect on the compressed result by the parameters in the LFM pulse, experiments were carried out for testing a steel plate with. two buried slots, both by the traditional TOFD method and the new method presented in this paper. The new method could reduce the minimum time resolution to 0.34 mu s, which is the time difference between the lateral wave and the upper diffracted wave. These results show that the pulse compression technique is a useful tool for improving the time resolution in ultrasonic TOFD testing. This is helpful for small defect detection and evaluation.